How are Timestrip® PLUS products evaluated for their time accuracy?

Timestrip® PLUS are polymeric multi-layer indicators. They are based on spontaneous lateral wetting by a blue liquid inside a porous substrate and not a chemical reaction. Each production batch (7000 – 8000 products) undergoes strict quality control tests to validate its time accuracy.

This is conducted via a computer vision software (TSCV) which analyses scanned photos of seven randomly-selected products from each batch (roughly 0.1% of the population). The photos are taken at different elapsed times and the tested products are placed at their designated temperature through the entire test period. The software automatically analyses the lateral progress and the elapsed time of each product tested and the data is presented numerically and graphically in a specific file which is labelled by batch. This data is translated into a final release report which is attached to the outgoing product batches.